Abbey Systems
  • Home
  • About
    • History
    • Our People
  • Latest News
  • Products
    • Aspex SCADA HMI software
    • Powerlink Telemetry Server SCADA software
    • Remote Access >
      • WebAlarm - Browser based access for smartphones
      • Securelink - Encrypted remote laptop PC access
    • SCADA Gateways - IP to Radio communications interfaces
    • Powercat RTU - Substation Monitoring & Control
    • Topcat RTU - Feeder Line Automation
    • Swampfox RTU - Pump Station & Reservoir Controller
    • Fox - Fibre Optic Converters
    • Accessories
  • Papers
    • Resilience in Water & Wastewater Telemetry & Control Systems 2015
    • Telemetry Communications Present & Future 2010
    • Telemetry Communications of the Future 2003
    • Evolution of SCADA Systems 2003
    • Telemetry / SCADA Open vs Proprietary Systems 2003
    • Getting more from your sewage pumping network 2000
  • SCADA Applications
    • Load Management System
    • HVDC Power - Fast Reaction Emergency Dump System
    • Pump Station Controller Program suite
    • Frequently Asked Questions
  • Case Studies
    • Gas SCADA Systems >
      • Powerco Gas Reticulation Cellular SCADA System
      • Synfuels - Gas pipeline monitoring & leak detection
      • Caltex Oil EMS
      • Petralgas Pipeline SCADA
    • Water & Wastewater SCADA Systems >
      • Neahkahnie, OR, USA
      • Rotorua DC, New Zealand
      • SCADA Experience - water & wastewater systems
    • Power & Energy SCADA Systems >
      • Bangladesh, Chittagong 33/11kV SCADA System
      • Devonport Naval Base Energy Management & Billing
      • SCADA Experience - Power & Gas systems
  • Links
  • Contact

Powerlink
Telemetry Server SCADA software


Powerlink is Abbey Systems' Telemetry Server software and is supplied bundled with Aspex into six different packages:
  • Aspex Full  - 100 RTU addresses, 500 programs
  • Aspex Standard  - 100 RTU addresses, 250 programs
  • Aspex Lite  - 25 RTU addresses, 100 programs 
  • Aspex Superlite - 7 RTU addresses, 25 programs
  • Aspex Local Operator  - 1 RTU, trends, programs & reports. No Alarm system.
                    
Powerlink is also available in the following versions:
  • Powerlink Telemetry Server with OPC Server interface for customers who want to use Abbey Systems RTUs with remote configuration, synchronous data transmission or Datalogging features, but still interface to Intouch, iFix, Citect or other HMIs with an OPC client. 
  • Powerlink Local Master for customers to configure RTUs using DNP3 slave serial or DNP3/TCP protocols to communicate with their SCADA Master
                     * US build specifications may differ

Powerlink comprises ...


Programs
  • Create programs online in realtime
  • Run programs at the SCADA Master or in the RTU (same language is used in both places)
  • MPL Programming language uses IF, AND, FOR, DO Boolean statements
  • Programs are self-documenting
  • Specific Telemetry Program instructions
  • Combine Telemetry and Datalogging instructions in programs
  • 4 Pump program suite available
  • Load Management suite available



Reports
  • Flexible Report creation by I/O, RTU & Alarm Action over date ranges
  • Quick Reports for Automated report generation to local or Network printers
  • Formatted reports
  • Report output as CSV or SQL format
  • Report on data collected in response to Polls & RTU Data Log file retrieval
Core
  • I/O Database configuration, tag shorthand and description
  • Communications Channel configuration
  • Input conditioning & filtering
  • Setup for Status, Measurements, Control Outputs, Analog Outputs, Pulse Counts and rates
  • Store measurements and statuses to Event file & Log file for later reporting


Communications

  • VHF Radio, UHF Radio, 2w Line, Ethernet, Cellular, Data radio, WiFi radio communications channel setup
  • Protocol setup Modbus Master & Slave, DNP3 Master & Slave, DNP3/TCP Modbus/TCP, Cooper 2179, Allen Bradley DF-1 Master & Slave
  • Abbey native protocol:  HDLC, Async HDLC & HDLC/IP
  • Download programs over the communications channel *
  • Retrieve Time stamped data log measurements and statuses from RTUs over the communications channel*
  • Concurrent protocols setup via IP, DNP3 slave of poll response & HDLC for remote setup and configuration or programming of RTUs
* Abbey native comms protocol feature
Alarms
  • Alarm on exceeding a Measurement setpoint or change of Digital Input state at a remote site
  • 80 custom Alarm Actions
  • Create a custom Alarm hierarchy
  • Send alarms to pagers, or cellphones with extra SMS software and appropriate modem
  • Working Hours Alarm Management
  • Duty Operator change  
  • Email Alarm notification option



Optional software modules
  • OPC Server
  • SQL /ODBC export 
  • Hot Standby SCADA Backup
  • CSV import
  • SMS Execute
  • Datalogging module
  • FTP export XML
  • Soap interface 
  • Load Management System suite
  • Pump Station system suite
  • WebAlarm for cellphones & desktop browsers
  • Securelink for Aspex & Powerlink IP access
  • RTU Capacity increase 100 RTU blocks
  • Number of Programs 250 & 500 blocks


Recommended Computer Hardware & Operating Systems

Recommended PC Hardware:          HP EliteDesk 800 SFF i5-4570 4GB 500GB DVDRW Win7Pro-64
Recommended Server Hardware:    IBM x3250 M4 1U rack mount
Operating System:                          MS WIN7, MS Server 2008R2, MS Server 2012R2
Virtualisation:                                 VMware ESX, Oracle Virtualbox